PolySULFOETHYL A™ HPLC Column
제품명: PolySULFOETHYL A™ HPLC Column
용도: Cation-Exchange of Peptides
메이커: PolyLC
카달로그: 다운로드


소개


PolySULFOETHYL A™



for Cation-Exchange of Peptides

 

 


This strong cation-exchange (SCX) material was developed specifically for HPLC of peptides. At pH 2.7-3.0, peptides lose their (-) charges and have net (+) charge. Thus, PolySULFOETHYL A™ is a general-purpose alternative to reversed-phase (RPC), fractionating peptides by differences in charge rather than polarity. Compared to other SCX materials based on sulfopropyl- (SP-) groups, 


PolySULFOETHYL A™ is unusually hydrophilic. This minimizes hydrophobic interactions with peptides, with high recovery and less peak tailing. Capacity is also high, permitting better retention and fractionation of the weakly basic peptides from tryptic digests. The capacity of an ion-exchange material like this is 4x that of a comparable RPC column. Therefore, ion-exchange should be the initial step of a multi-step purification.  

 


Use PolySULFOETHYL A™ for:


   1) Multidimensional HPLC of peptide mixtures, such astryptic digests in proteomics analyses (including iTRAQ® and ICAT®* reaction products).


   2) Isolation of peptides from natural products.


   3) QC and purification of synthetic peptides.


   4) Selective isolation of disulfide-linked peptides, phosphopeptides and C-terminal fragments from tryptic digests.


   5) Mapping of peptide digests (tryptic, V8, CNBr, etc.).



Proteins can be run on PolySULFOETHYL A™ columns too; at pH 3, retention is all but guaranteed. An example is the analysis of Lung Surfactant Protein on a PolySULFOETHYL A column operated in the Hydrophilic Interaction (HILIC) mode.

Standard material for peptide applications is 300-Å, in either 3- or 5-µm. The 200-Å material has about 25% greater capacity and is preferred for phosphopeptide isolation and fractionation of iTRAQ® reaction mixtures. For proteins, use 1000-Å material or the 3-µm, 1500-Å material.


주문정보

Columns Available with 3µm Particles(Pore Size Options: -03, -10, -15)

 

 Column Dimensions  Item Number
 50 x 1.0mm  051SE03--
 100 x 1.0mm  101SE03--
 50 x 2.1mm  052SE03--
 100 x 2.1mm  102SE03--
 35 x 4.6mm  3.54SE03--
 50 x 4.6mm  054SE03--
 100 x 4.6mm  104SE03--
 100 x 9.4mm  109SE03--

 


Columns Available with 5µm Particles(Pore Size Options: -02, -03, -10)

 

 Column Dimensions  Item Number
 50 x 1.0mm  051SE05--
 100 x 1.0mm  101SE05--
 150 x 1.0mm  151SE05--
 35 x 2.1mm  3.52SE05--
 50 x 2.1mm  052SE05--
 100 x 2.1mm  102SE05--
 200 x 2.1mm  202SE05--
 35 x 4.6mm  3.54SE05--
 50 x 4.6mm  054SE05--
 100 x 4.6mm  104SE05--
 200 x 4.6mm  204SE05--
 100 x 9.4mm  109SE05--
 200 x 9.4mm  209SE05--
 250 x 9.4mm  259SE05--
 250 x 21.0mm  2521SE05--

   


Columns Available with 12µm Particles(Pore Size Options: -03, -15) 

 

 Column Dimensions  Item Number
 200 x 4.6mm  204SE12--
 200 x 9.4mm  209SE12--
 250 x 9.4mm  259SE12--
 250 x 21.0mm  2521SE12--
 250 x 50.8mm  2550SE12--

 


Capillaries Available with 5µm Particles*(Pore Size Options: -02, -03, -10)**


 50mm x  150µm  050.15SE05--
 100mm x 150µm  100.15SE05--
 150mm x 150µm  150.15SE05--
 50mm x 300µm  050.30SE05--
 100mm x 300µm  100.30SE05--
 150mm x 300µm  150.30SE05--

 


Solid Phase Extraction Cartridges - 10 packs


 SPESE1203  12µm, 300Å
 SPESE1215  12µm, 1500Å
 SPESE2003  20µm, 300Å
 SPESE2015  20µm, 1500Å

 

 

Javelin Guard Cartridges - each

("J" = Javelin format; no holder needed) [NOTE: CPI-detail. To get Waters detail,  add "W" to the item#]

 

 10 x 1.0mm  J11GCSE05--
 10 x 2.0mm  J22GCSE03--
 10 x 2.0mm  J22GCSE05--
 10 x 3.0mm  J33GCSE03--
 10 x 3.0mm  J33GCSE05--
 10 x 4.0mm  JGCSE03--
 10 x 4.0mm  JGCSE05--
 20 x 4.0mm  JGCSE03--  -2
 20 x 4.0mm  JGCSE05--  -2
 10 x 10mm
  (CH10 holder needed)
 110GCSE05--
 10 x  10mm
  (CH10 holder needed)
 100GCSE12--
 HOLDER  CH10
 20 X 10.0mm  (ask)



FORMULATING A COMPLETE ITEM NUMBER


The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.

Example of a complete item number: 204CT05-- designates a PolyCAT A column, 200x4.6mm,

packed with 5-µm material. If you want 1000-Å pores, then add -10 to the end. 

The complete item number is then 204CT0510.