Product
소개
PolyGLYCOPLEX A™
for HILIC of Complex Carbohydrates
This neutral material has the unusually high capacity needed to retain complex carbohydrates in the HILIC mode.
Columns can frequently be operated with just acetonitrile and water, although charged carbohydrates may require inclusion of some salt such as ammonium acetate. These conditions are convenient for isolation of carbohydrates or direct flow to a mass spectrometer.
Selectivity is good for both native glycans and derivatives such as those with the 2-aminopyridine (PA-) fluorophore.
Oligosaccharide mixtures can often be resolved isocratically, although gradients are recommended for especially varied samples.
Sialylated and asialo- glycans can be resolved using the same running conditions.
In some cases selectivity compares favorably with that of HPAEC with PAD detection, and both running conditions and equipment maintenance are far more convenient.
주문정보
Columns with 3µm Particles
Column Dimensions | Item Number |
50 x 1.0mm | 051GL0300 |
100 x 1.0mm | 101GL0300 |
50 x 2.1mm | 052GL0300 |
100 x 2.1mm | 102GL0300 |
35 x 4.6mm | 3.54GL0300 |
50 x 4.6mm | 054GL0300 |
100 x 4.6mm | 104GL0300 |
100 x 9.4mm | 109GL0300 |
Columns with 5µm Particles
Column Dimensions | Item Number |
50 x 1.0mm | 051GL0500 |
100 x 1.0mm | 101GL0500 |
150 x 1.0mm | 151GL0500 |
35 x 2.1mm | 3.52GL0500 |
50 x 2.1mm | 052GL0500 |
100 x 2.1mm | 102GL0500 |
200 x 2.1mm | 202GL0500 |
35 x 4.6mm | 3.54GL0500 |
50 x 4.6mm | 054GL0500 |
100 x 4.6mm | 104GL0500 |
200 x 4.6mm | 204GL0500 |
100 x 9.4mm | 109GL0500 |
200 x 9.4mm | 209GL0500 |
250 x 9.4mm | 259GL0500 |
250 x 21.0mm | 2521GL0500 |
Columns Available with 12µm Particles
Column Dimensions | Item Number |
200 x 4.6mm | 204GL1200 |
200 x 9.4mm | 209GL1200 |
250 x 9.4mm | 259GL1200 |
250 x 21.0mm | 2521GL1200 |
250 x 50.8mm | 2550GL1200 |
Capillaries Available with 5µm Particles*(Pore Size Options: -02, -03, -10)**
50mm x 150µm | 050.15GL0500 |
100mm x 150µm | 100.15GL0500 |
150mm x 150µm | 150.15GL0500 |
50mm x 300µm | 050.30GL0500 |
100mm x 300µm | 100.30GL0500 |
150mm x 300µm | 150.30GL0500 |
* 3-µm capillaries are available at the same price as 5-µm | |
Change"0500" to "0300" |
Solid Phase Extraction Cartridges - 10 packs
SPEGL1201 | 12µm |
SPEGL2001 | 20µm, 100Å |
Javelin Guard Cartridges - each
("J" = Javelin format; no holder needed) [NOTE: CPI-detail. To get Waters detail, add "W" to the item#]
10 x 1.0mm | J11GCGL0500 |
10 x 2.0mm | J22GCGL0300 |
10 x 2.0mm | J22GCGL0500 |
10 x 3.0mm | J33GCGL0300 |
10 x 3.0mm | J33GCGL0500 |
10 x 4.0mm | JGCGL0300 |
10 x 4.0mm | JGCGL0500 |
20 x 4.0mm | JGCGL0300 -2 |
20 x 4.0mm | JGCGL0500 -2 |
10 x 10mm | 110GCGL0500 |
(CH10 holder needed) | |
10 x 10mm | 100GCGL12-- |
(CH10 holder needed) | |
HOLDER | CH10 |
20 X 10.0mm | (ask) |
FORMULATING A COMPLETE ITEM NUMBER
The item numbers in this list require additional numbers at the end to designate the pore diameter:
Numbers: -006, -01, -02, -03, -05, -10, and -15 correspond to the following pore diameters:
60 Å, 100 Å, 200 Å, 300 Å, 500 Å, 1000 Å, and 1500 Å, respectively.
Example of a complete item number: 204CT05-- designates a PolyCAT A column, 200x4.6mm,
packed with 5-µm material. If you want 1000-Å pores, then add -10 to the end.
The complete item number is then 204CT0510.